Skip to content
Free delivery from €79
Product

Trotec PC220 Particle Counter 6-Channel

4.6/5·194 reviews
Trotec PC220 Particle Counter 6 Channel - PM2.5 PM10 HCHO CO Air Quality Monitor
Trotec PC220 Particle Counter 6 Channel - PM2.5 PM10 HCHO CO Air Quality Monitor
Trotec PC220 Particle Counter 6 Channel - PM2.5 PM10 HCHO CO Air Quality Monitor
Trotec PC220 Particle Counter 6 Channel - PM2.5 PM10 HCHO CO Air Quality Monitor
Trotec PC220 Particle Counter 6 Channel - PM2.5 PM10 HCHO CO Air Quality Monitor
-45%
559.35€incl. tax·466.12€ excl. tax
Instead of1017.00€incl. tax·847.50€ excl. tax
You save (-45%)
In Stock All in your cart Out of Stock
Portable laser particle counter Trotec PC220, ISO 21501-4 standard. Analyzes 6 channels from 0.3 to 10 µm, measures PM10/PM2.5 in µg/m³, detects formaldehyde (HCHO) and carbon monoxide (CO). Features humidity, temperature, dew point, photo-video camera and 2.8" color display. Memory 5,000 measurements, expandable 16 GB. Ideal for air quality control, buildings and sensitive industrial processes.

Order before to receive from Wednesday 1 April

Free shipping

On this order

Estimated delivery

from Wednesday 1 April

Order within 11h 02min

Easy returns

Return possible until 1 May 2026

Share
Particle Counter PC 220 - TROTEC

The PC220 particle counter is a portable measuring device combining particle analysis, gas detection, and climate control. Compliant with ISO 21501-4 standard, it features a photo-video camera to document each reading and facilitate indoor air quality monitoring in industrial, medical, or building environments.

Simultaneous measurements and intuitive display

The device evaluates six particle size channels in parallel, ranging from 0.3 to 10 µm. It also detects fine dust PM10 and PM2.5 expressed directly in µg/m³, while measuring formaldehyde (HCHO) and carbon monoxide (CO) gases. All data is displayed on a 2.8" color LCD screen with color bar and audible alarm in case of critical threshold exceedance.

Integrated environmental parameters

In addition to particle counting and gases, the PC220 tracks the following data:

  • Relative humidity
  • Air temperature
  • Dew point
  • Wet bulb temperature

  • Data storage and export

    The PC220 records up to 5,000 measurements in its internal memory, expandable to 16 GB via MicroSD card. Thanks to the USB connection, results can be quickly transferred to a PC for processing or archiving.

    Main applications

  • Indoor air quality control: compliance with health thresholds and pollutant detection
  • Building technical management: verification of ventilation networks and filter monitoring
  • Sanitation: detection of partition leaks during renovation work
  • Industrial filters: efficiency control and prevention of seal failures
  • Sensitive processes: monitoring of micro and nanoparticles (dust, aerosols, bacteria)

  • PC220 key features

  • 6 channels from 0.3 to 10 µm for particle counting
  • PM10 and PM2.5 measurement in µg/m³
  • Integrated HCHO and CO detection
  • Filter efficiency evaluation
  • Climate parameters: RH, T°, dew point, wet bulb T°
  • Integrated photo/video camera
  • Memory 5,000 data points, expandable MicroSD 16 GB
  • Backlit color LCD screen
  • Audible alarm and color display
  • Ergonomic one-hand use and tripod threading

  • A precise tool for formaldehyde detection

    Equipped with an HCHO sensor capable of measuring from 0.01 ppm, the PC220 meets the requirements related to the reclassification of formaldehyde as a carcinogenic substance in Europe. It contributes to risk assessment, regulatory documentation, and prevention of prolonged exposures.

    Quantitative measurement of fine dust

    The PC220 relies on the international PM classification (EPA) to quantify PM10 and PM2.5 dust. These readings are essential to limit the health impact of alveolar particles and ensure reliable monitoring in work environments.

    About the Trotec brand

    Trotec specializes in the manufacturing and distribution of air treatment and precision measurement equipment. Recognized for its innovation and Made in Germany quality, Trotec offers a complete range of products including dehumidifiers, humidifiers, environmental measuring devices, and much more, designed to meet the needs of professionals and individuals. With a focus on sustainability, energy efficiency, and performance, Trotec is committed to providing reliable and effective solutions to improve air quality and comfort in various living and working spaces.
    BrandTrotec
    SKU4742863610
    EAN/GTIN4052138012796
    MPN3510006015
    CategoryEmission Measurement
    Condition New
    Detailed Technical Specifications

    General Information
    Brand: Trotec
    Model: PC 220
    Supplier Reference: 3510006015
    EAN Code: 4052138012796
    Dimensions (h x w x d): 240 mm x 75 mm x 57 mm
    Weight: 570 g
    Tripod Thread: 1/4 inch – 20 UNC
    PC Interfaces: USB Port

    Display and Power
    Screen: 2.8" color LCD with backlight, 320 x 240 pixels
    Battery: Lithium-ion polymer
    Battery Life: approximately 4 hours continuous operation
    Charging Time: approximately 2 hours with power adapter
    Auto Power Off: 3 min, 15 min or 60 min
    Auto Screen Off: 90 s, 2 min or 4 min

    Operating Conditions
    Operating Conditions: 0 °C to +50 °C and 10 to 90 % RH (non-condensing)
    Storage Conditions: -10 to +60 °C and 10 to 90 % RH (non-condensing)

    Light Source
    Type: Class 3R laser, wavelength 780 nm, 90 mW according to EN
    Measurement Cell: Class 1 laser (Class 3R laser encapsulated against any manipulation, 780 nm, 1.5-3 mW, classified according to DIN EN 60285-1 and "TROS Laser Radiation" regulation)

    Recording and Memory
    Internal Memory: 5,000 records in internal flash memory
    Memory Extension: microSD card up to 16 GB
    Image Format: JPEG, 640 x 480 pixels
    Video Format: 3GP, 320 x 240 pixels

    Functions
    Display of maximum, minimum and average values
    Hold function
    Alarm
    Language selection
    °C/°F switching
    Photo or video recording

    Temperature Measurements
    Temperature Range: 0 °C to 50 °C (32 °F to 122 °F)
    Accuracy: ±0.5 °C (0.9 °F) from 10 °C to 40 °C (50 °F to 104 °F), ±1.0 °C (1.8 °F) for other temperatures
    Dew Point - Range: 0 °C to 50 °C (32 °F to 122 °F)
    Dew Point - Accuracy: ±0.5 °C (0.9 °F) from 10 °C to 40 °C (50 °F to 104 °F), ±1.0 °C (1.8 °F) for other temperatures
    Wet Bulb - Range: 0 °C to 80 °C (32 °F to 176 °F)
    Wet Bulb - Accuracy: ±1.0 °C (1.8 °F)

    Humidity Measurements
    Measuring Range: 0 % RH to 100 % RH
    Accuracy: ±3 % RH from 40 % to 60 %, ±3.5 % RH from 20 % to 40 % and 60 % to 80 %, ±5 % RH from 0 % to 20 % and 80 % to 100 %

    Particle Counter
    Channels (detectable particle sizes): 0.3 μm, 0.5 μm, 1.0 μm, 2.5 μm, 5.0 μm, 10.0 μm
    PM Channels: PM2.5 / PM10
    Flow Rate: 2.83 l/min. (0.1 ft³/min.) controlled by internal pump
    Counting Mode: Cumulative, differential, concentration
    Counting Efficiency: 50 % for 0.3 μm; 100 % for particles > 0.45 μm (according to ISO 21501)
    Coincidence Error: 5 %, 2 million particles per 28.3 litres
    Zero Count: 1 count/5 minutes (according to JIS B9921)
    Delayed Start: 1 to 100 seconds
    Sample Inlet: Isokinetic probe
    Calibration: By monodisperse latex particles (PSL particles; according to NIST)

    PM2.5 / PM10 Particle Measurement
    Measuring Range: 0 to 2,000 μg/m³
    Resolution: 1 μg/m³

    Formaldehyde (HCHO) Measurement
    Measuring Range: 0.01 to 5.00 ppm
    Accuracy: ±5 % F.S
    Resolution: 0.01 ppm

    Carbon Dioxide (CO2) Measurement
    Measuring Range: 10 to 1,000 ppm
    Accuracy: ±5 % F.S
    Resolution: 1 ppm